Summary for Test 2024-10-11-67-8
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 66667 DEA: JMFPP EFIS: 0019000043 |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for submitting Sample information for JMF Prequalification Program. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 10/11/2024 | Sample Unique Key | 67 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/16/2024 |
| Sample type | Verification | A brief description of the sample | RWMA Aggregates |
| The quantity of what the sample constitutes | 7 bags | From where was the sample collected | Source |
| First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 1201-JMF | Linked DIME Sample ID | 2024-10-11-66 |
| The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Not Provided |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plnat | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number | 226110 Otay SJR |
Test Details
DIME Sample ID: 2024-10-11-67
DIME Test ID: 2024-10-11-67-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2024-10-25
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 10/25/2024
Mass of measure: 189.6 grams
Bulk dry specific gravity: 2.569
Mass of sample and measure #1: 328.9 grams
Mass of sample and measure #2: 328.8 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 139.3 grams
Mass of sample #2: 139.2 grams
Uncompacted voids #1: 45.8 %
Uncompacted voids #2: 45.8 %
Average uncompacted voids: 45.8 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/25/2024 ✔