Summary for Test 2024-10-22-49-4
Test performed: AASHTO T304-11Project Information
| Project Identifiers | Project ID: 215771 DEA: 09367504 EFIS: 0916000032 |
|---|---|
| DIST-CO-RTE-PM | 09--5756-NA |
| Award Date | 03/23/2023 |
| Closeout Date | 11/10/2025 |
| Work Description | Building work, hot mix asphalt (type A) |
| Location Description | IN KERN COUNTY IN TEHACHAPI AT THE TEHACHAPI HIGHWAY MAINTENANCE STATION AT 305 INDUSTRIAL PARKWAY |
| QA Service Level | 1 (Verified on 05/13/2021) |
Sample Information
| Sample Taken Date | 10/22/2024 | Sample Unique Key | 49 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA-A-SP PG58-34M R25 |
| The quantity of what the sample constitutes | Production Start Up | From where was the sample collected | Source |
| First name of sampler or witnessed by | Granite QC | Last name of sampler or witnessed by | Granite QC |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | CF-PSU-1 SL-1 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Granite Solari Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 00-00-0000 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Sample Device at Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-10-22-49
DIME Test ID: 2024-10-22-49-4
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2024-10-25
Test Results
What test method is performed?: Method A
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 10/25/2024
Mass of measure: 189.3 grams
Bulk dry specific gravity: 2.71
Mass of sample and measure #1: 333.6 grams
Mass of sample and measure #2: 334.0 grams
Volume of cylinder: 100.0 mL
Mass of sample #1: 144.3 grams
Mass of sample #2: 144.7 grams
Uncompacted voids #1: 46.8 %
Uncompacted voids #2: 46.6 %
Average uncompacted voids: 46.7 %
General comments (publicly viewable) (Max 1000 characters): PSU 01 SL-1
Test was verified on 10/25/2024 ✔