Summary for Test 2024-10-18-34-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215741 DEA: 01366004 EFIS: 0100000127 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-80.0/84.0 |
Award Date | 12/29/2022 |
Closeout Date | Not set |
Work Description | Indianola Cutoff UC |
Location Description | HUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF |
QA Service Level | 1 (Verified on 05/17/2021) |
Sample Information
Sample Taken Date | 10/18/2024 | Sample Unique Key | 34 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2024 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 150 hoops | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Peter | Last name of sampler or witnessed by | Harvey |
Title of sampler | Assistant METS Representative | Telephone number of sampler | (707) 364-2452 |
Laboratory sample identification | Linked DIME Sample ID | 2024-10-18-1 | |
The fabricator/manufacturer/facility name | Conco Companies Benicia | Transportation Laboratory (TL) Number | TL-6034 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S74-023-24 | Structure unique identifier | 04-0314 |
Structure name | Eureka Slough |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4135963 |
Hoop Manufacturer Lot Number(s) | H100 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 1'-6.5" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel Arizona |
Welding Company | Conco Companies Benicia | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2024-10-18-34
DIME Test ID: 2024-10-18-34-2
Testing Lab: Kleinfelder, Incorporated - Sacramento
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Necking)
Test Release Date: 2024-10-25
Test Results
Necking Test Option: Necking Test Option I
Shape of the Sample: Hoop
Input Type: Calculated
Tester's full name: Kevin DeSouza
Date of test: 10/23/2024
Sample 1 Visible Necking?: Yes
Sample 1 Location of Fracture?: Bar
Sample 2 Visible Necking?: Yes
Sample 2 Location of Fracture?: Bar
Sample 3 Visible Necking?: Yes
Sample 3 Location of Fracture?: Bar
Sample 4 Visible Necking?: Yes
Sample 4 Location of Fracture?: Bar
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/25/2024 ✔