Summary for Test 2024-10-22-45-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995059
DEA: 081G6404
EFIS: 0816000046
DIST-CO-RTE-PM08-SBD-395-R4.0/49.0
Award Date10/25/2023
Closeout DateNot set
Work DescriptionREPLACE ASPHALT CONCRETE SURFACING, COLD PLANE AC PVMT AND RHMA.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM ROUTE 15/395 SEPARATION TO 3.1 MILES NORTH OF ROUTE 58/395 SEPARATION
QA Service Level1 (Verified on 08/15/2023)

Sample Information

Sample Taken Date10/22/2024 Sample Unique Key45
Date that the sample was received by the laboratory/organization performing the testing10/23/2024 Sample typeAcceptance
A brief description of the sample3/4" RHMA-G-SP 1% LSM The quantity of what the sample constitutes4 boxes of HMA,1 qt of virgin and blended binder
From where was the sample collectedManufacturer First name of sampler or witnessed byFernando
Last name of sampler or witnessed byCaranza Title of sampler
Telephone number of sampler Laboratory sample identification0570G-24
Linked DIME Sample ID The fabricator/manufacturer/facility nameBlue Diamond-Victorville
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number1
Sublot number111 HMA Mix Number300072 LSM
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-10-22-45
DIME Test ID: 2024-10-22-45-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-25

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 10/24/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2143.5 g
Mass Loss: 179.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.24 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 8.02 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/25/2024 ✔