Summary for Test 2024-10-17-44-1
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 994332 DEA: 11430444 EFIS: 1118000204 |
|---|---|
| DIST-CO-RTE-PM | 11-IMP-8,78-Var |
| Award Date | 12/22/2022 |
| Closeout Date | 01/27/2025 |
| Work Description | REHABILITATE BRIDGES, CONCRETE BARRIERS, TERMINAL SYSTEMS, ELECTRICAL. |
| Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 02/21/2023) |
Sample Information
| Sample Taken Date | 10/17/2024 | Sample Unique Key | 44 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/21/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinders |
| The quantity of what the sample constitutes | 8 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Joseph | Last name of sampler or witnessed by | Seymour |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 8812-C | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Gibson Shaefer | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 22044 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | NOT PROVIDED | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Job Site | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-17-44
DIME Test ID: 2024-10-17-44-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-24
Test Results
Number of specimens: 2
Input Type: Calculated
Tester's full name: Melchor Oronoz
Date of test: 10/24/2024
Correction factor: 1
Cylinder Age: 7 days
Break Description of Cylinder 1 (if not 'cone'): no data
Break Description of Cylinder 2 (if not 'cone'): no data
Average Compressive Strength (to nearest 10): 4426 lb/in^2
Compressive Strength of Cylinder 1: 4498 lb/in^2
Compressive Strength of Cylinder 2: 4354 lb/in^2
General comments (publicly viewable) (Max 1000 characters): 7 days, 4426 psi
Test was verified on 10/24/2024 ✔