Summary for Test 2013-09-26-7558499-7
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7780 DEA: 112T1824 EFIS: 1100020051 |
---|---|
DIST-CO-RTE-PM | 11-SD-805-4.7/5.6 |
Award Date | 01/03/2013 |
Closeout Date | 09/07/2018 |
Work Description | REPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR). |
Location Description | SAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 12/10/2012) |
Sample Information
Sample Taken Date | 09/26/2013 | Sample Unique Key | 7558499 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | Not set |
Sample type | Quality Control | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 4 cylinders | From where was the sample collected | Source |
First name of sampler or witnessed by | Halden | Last name of sampler or witnessed by | George |
Title of sampler | CWE Lab Tech | Telephone number of sampler | (925) 989-6385 |
Laboratory sample identification | 2013-09-26-0755 | Linked DIME Sample ID | Not set |
The fabricator/manufacturer/facility name | Vulcan | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | Not set | |
Structure name | Not set |
Material Information
Material Type | Concrete | The concrete mix design number | 103612F |
---|---|---|---|
The truck number from where the sample was collected | Not set | The batch plant ticket number from where the sample was collected | 151116 |
Concrete batch plant | Not set | The fabricator/manufacturer designation for the sample | Not set |
A detailed description of where the material sample was collected | Pylaster 4 5 6 on sound barrier wall at midpoint | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2013-09-26-7558499
DIME Test ID: 2013-09-26-7558499-7
Testing Lab: Vulcan Materials Company - San Diego
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2014-01-27
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Christian Wheeler
Date of test: 10/03/2013
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 80750 lb
Maximum load on cylinder 2: 77470 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 7 days
Cross sectional area of cylinder 1: no data
Cross sectional area of cylinder 2: no data
Compressive strength (to nearest 10 psi): 2800 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/27/2014 ✔