Summary for Test 2024-10-18-29-3
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 212800 DEA: 100G8304 EFIS: 1012000316 |
|---|---|
| DIST-CO-RTE-PM | 10-MER-152,140,152-Var |
| Award Date | 10/31/2023 |
| Closeout Date | 06/23/2026 |
| Work Description | MERCED SEISMIC RESTORATION |
| Location Description | IN MERCED COUNTY ON STATE ROUTES, 59, 140 AND 152 AT VARIOUS BRIDGES. |
| QA Service Level | 1 (Verified on 12/20/2018) |
Sample Information
| Sample Taken Date | 10/18/2024 | Sample Unique Key | 29 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/19/2024 | Sample type | Quality Control |
| A brief description of the sample | WCS | The quantity of what the sample constitutes | 1 Day |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Todd |
| Last name of sampler or witnessed by | Strait | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Central Valley Concrete | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | central valley concrete |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | fine | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-10-18-29
DIME Test ID: 2024-10-18-29-3
Testing Lab: RMA Group - Rancho Cordova
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-10-24
Test Results
Number of tests: 1
Input Type: Calculated
Tester's full name: Todd Strait
Date of test: 10/19/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 53
Sand reading (test 1): 44
Sand equivalent (test 1): 84
Sand equivalent before temperature correction: 84
Sand equivalent after temperature correction: 84
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/24/2024 ✔