Summary for Test 2024-10-16-14-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215348
DEA: 060U4204
EFIS: 0616000004
DIST-CO-RTE-PM06-FRE-99-R4.9/11.6
Award Date02/25/2021
Closeout Date12/02/2025
Work DescriptionCONSTRUCT CRCP, PLACE HMA, AND ROADWAY EXCAVATION.
Location DescriptionFRESNO COUNTY IN AND NEAR SELMA AND FOWLER FROM MCCALL AVENUE UNDERCROSSING TO 0.5 MILE NORTH OF MERCED STREET UNDERCROSSING
QA Service Level1 (Verified on 12/07/2020)

Sample Information

Sample Taken Date10/16/2024 Sample Unique Key14
Date that the sample was received by the laboratory/organization performing the testing10/17/2024 Sample typeQuality Control
A brief description of the sample4X8 Concrete Cylinders The quantity of what the sample constitutes5
From where was the sample collectedJob Site First name of sampler or witnessed bySok
Last name of sampler or witnessed byThun Title of samplerCT ASR
Telephone number of sampler5592402128 Laboratory sample identificationMix NCT09064
Linked DIME Sample ID The fabricator/manufacturer/facility nameBuilder Concrete at Sanger Plant
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameCIDH Sign foundation
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberNCT09064
The truck number from where the sample was collectedLoad 2 The batch plant ticket number from where the sample was collected111351707
Concrete batch plantConcrete Builder at Sanger plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedShoulder of SB 99, STA 207+50 Where the material sample would have been placed if not sampledPedestal Sign foundation at Shoulder of SB 99, STA 207+50
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-16-14
DIME Test ID: 2024-10-16-14-2
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-24

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 10/24/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 38930 lb
Maximum load on cylinder 2: 39510 lb
Maximum load on cylinder 3: 38170 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3097.1 psi
Compressive strength of cylinder 2: 3143.2 psi
Compressive strength of cylinder 3: 3036.6 psi
Compressive strength (to nearest 10 psi): 3090 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/24/2024 ✔