Summary for Test 2024-10-07-71-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 212470
DEA: 044A1304
EFIS: 0400001106
COOP: 042718
DIST-CO-RTE-PM04-SON-101-18.5/18.5
Award Date11/17/2023
Closeout DateNot set
Work DescriptionCONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY
Location DescriptionIN SONOMA COUNTY.
QA Service Level1 (Verified on 09/23/2019)

Sample Information

Sample Taken Date10/07/2024 Sample Unique Key71
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/21/2024
Sample typeQuality Control A brief description of the sampleTYPE II / V
The quantity of what the sample constitutes5.25 CY From where was the sample collectedJob Site
First name of sampler or witnessed byJOEY Last name of sampler or witnessed byBUCKLER
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCEMEX-REDLANDS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number1610974
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected31370939
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedCONCRETE SAMPLE FROM WHEELBARROW Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-07-71
DIME Test ID: 2024-10-07-71-1
Testing Lab: Surecast West
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-22

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: JOEY BUCKLER
Date of test: 10/21/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 60520 lb
Maximum load on cylinder 2: 61160 lb
Maximum load on cylinder 3: 63960 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 14 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength (to nearest 10 psi): 4930 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/22/2024