Summary for Test 2017-08-18-3-4

Test performed: ASTM A722-15

Project Information

Project IdentifiersProject ID: 211690
DEA: 042A3204
EFIS: 0400000817
DIST-CO-RTE-PM04-NAP-121-9.2/9.4
Award Date12/01/2016
Closeout Date01/23/2019
Work DescriptionROADWAY WIDENING, BRIDGE REPLACEMENT, CREEK GRADING
Location DescriptionNAPA COUNTY IN NAPA AT SILVERADO TRAIL ROAD
QA Service Level1 (Verified on 01/03/2017)

Sample Information

Sample Taken Date08/18/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing08/25/2017 Sample typeQuality Assurance
A brief description of the sampleASTM A722 The quantity of what the sample constitutes2
From where was the sample collectedSource First name of sampler or witnessed byMargarito
Last name of sampler or witnessed byMargarito Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form Eng
Transportation Laboratory (TL) NumberC647234 Inspector Lot Number from the Transportation Laboratory (TL) FormL7300917
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingAuthorization Testing
Threaded Bar SpecificationASTM A722 Threaded Bar Grade150
Threaded Bar TypeDeformed Rebar Size1
Nut Specification for Threaded BarASTM A29 System ManufacturerWilliams Form Eng
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)62142446
Nut Heat Number(s)NF15203286 Bar Lot NumberUnknown
Nut Lot Number26F1D Coupler Heat Number(s)Unknown
Coupler GradeUnknown

Test Details

DIME Sample ID: 2017-08-18-3
DIME Test ID: 2017-08-18-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A722-15: Standard Specification for High-Strength Steel Bars for Prestressed Concrete (Tensile)
Test Release Date: 2017-09-04

Test Results


Number of Threaded Bar Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 08/25/2017
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)Reduction of area (%)CommentsTested By
12A722 WilliamsI 1\" Threaded Bar & NutL73009170.851690191327728.10A722 Bar & NutFred

General comments (publicly viewable) (Max 1000 characters): A722 Bar & Nut
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 8/28/2017 ✔