Summary for Test 2024-10-11-60-2
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 995193 DEA: 07356604 EFIS: 0719000026 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-605-R10.2/20.2 |
| Award Date | 04/04/2024 |
| Closeout Date | Not set |
| Work Description | LANE & SLAB REPLACEMENT, COLD PLANE & HMA OVERLAY. |
| Location Description | LOS ANGELES COUNTY IN SANTA FE SPRINGS, PICO RIVERA, WHITTIER, CITY OF INDUSTRY AND EL MONTE FROM TELEGRAPH ROAD UNDERCROSSING TO ROUTE 605/10 SEPARATION |
| QA Service Level | 1 (Verified on 10/03/2023) |
Sample Information
| Sample Taken Date | 10/11/2024 | Sample Unique Key | 60 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 1 Set of 1x4 PCC Aggregates |
| The quantity of what the sample constitutes | 120 CY | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Hussaya | Last name of sampler or witnessed by | Leelakitrungruang |
| Title of sampler | Field Materials Tester | Telephone number of sampler | 6265343017 |
| Laboratory sample identification | 24-10-006 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Saragosa Whittier | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Martin Murietta-Irwindale |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
| The concrete mix design number | VCTS675 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-10-11-60
DIME Test ID: 2024-10-11-60-2
Testing Lab: Kleinfelder, Incorporated - Los Angeles
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-10-18
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Hussaya Leelakitrungruang
Date of test: 10/11/2024
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 96 % | ||||||
| 81 % | ||||||
| 68 % | ||||||
| 49 % | ||||||
| 25 % | ||||||
| 8 % | ||||||
| 2.9 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/18/2024 ✔