Summary for Test 2024-10-09-1-5

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date10/09/2024 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/09/2024
Sample typeQuality Assurance A brief description of the sampleConcrete for abutment cidh
The quantity of what the sample constitutes~11CY of SR 3/8s CIDH From where was the sample collectedJob Site
First name of sampler or witnessed byBarrett Last name of sampler or witnessed byUpdegraff
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2024-10-09
The fabricator/manufacturer/facility nameTidewater Contractors Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameDr. Fine Bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberSR 3/8s CIDH
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected61515
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedfrom mix truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-10-09-1
DIME Test ID: 2024-10-09-1-5
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-16

Test Results


Number of specimens: 3
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 10/16/2024
Correction factor: 1
Cylinder Age: 7 days
Break Description of Cylinder 1 (if not 'cone'): 5
Break Description of Cylinder 2 (if not 'cone'): 5
Break Description of Cylinder 3 (if not 'cone'): 5
Average Compressive Strength (to nearest 10): 2810 lb/in^2
Compressive Strength of Cylinder 1: 3050 lb/in^2
Compressive Strength of Cylinder 2: 2480 lb/in^2
Compressive Strength of Cylinder 3: 2900 lb/in^2
General comments (publicly viewable) (Max 1000 characters): 10/16/24 7 day breal

Test was verified on 10/16/2024