Summary for Test 2017-07-27-5-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 211304 DEA: 07302604 EFIS: 0713000483 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-57-R4.4/R12.1 |
| Award Date | 07/22/2016 |
| Closeout Date | 06/16/2021 |
| Work Description | REPLACE CONCRETE PAVEMENT, COLD PLANE AND PLACE HMA PAVEMENT. |
| Location Description | LOS ANGELES COUNTY FROM ROUTE 57/60 SEPARATION IN DIAMOND BAR TO ROUTE 57/210 SEPARATION IN GLENDORA |
| QA Service Level | 1 (Verified on 05/30/2017) |
Sample Information
| Sample Taken Date | 07/27/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 07/28/2017 | Sample type | Quality Assurance |
| A brief description of the sample | 6x12 concrete cylinders | The quantity of what the sample constitutes | 2 6x12 cylinders |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | George |
| Last name of sampler or witnessed by | Lujan | Title of sampler | QAI |
| Telephone number of sampler | 951 640-5331 | Laboratory sample identification | Unknown |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | Pro Cast Products |
| Transportation Laboratory (TL) Number | Unknown | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | Route 57 and 60 Pavement slabs | Structure name | Precast Pavement Slabs |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | RRM-14062 |
|---|---|---|---|
| The truck number from where the sample was collected | 14 | The batch plant ticket number from where the sample was collected | 3056018 |
| Concrete batch plant | Robertsons Ready Mix | The fabricator/manufacturer designation for the sample | Load 4 |
| A detailed description of where the material sample was collected | Wheel Barrow from Chute | Where the material sample would have been placed if not sampled | Precast Pavement Slabs |
| From Lot No. | Load 4 | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-07-27-5
DIME Test ID: 2017-07-27-5-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-08-24
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/24/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.03 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 172880 lb
Maximum load on cylinder 2: 171220 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.56 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 6053.2 psi
Compressive strength of cylinder 2: 6035.2 psi
Compressive strength (to nearest 10 psi): 6040 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/24/2017 ✔