Summary for Test 2024-10-09-51-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 995229
DEA: 07355404
EFIS: 0719000010
DIST-CO-RTE-PM07-LA-2,210-15.0/57.5,R18.7/R19.4
Award Date01/30/2024
Closeout DateNot set
Work DescriptionREPLACE AND INSTALL DRAINAGE SYSTEM, AND PERFORM SLOPE PAVING.
Location DescriptionLOS ANGELES COUNTY ON ROUTE 2 FROM 1.0 MILE NORTH OF CLIFFORD STREET TO MOUNT WATERMAN SKI LIFTS AND ON ROUTE 210 FROM 0.5 MILE EAST OF OCEAN VIEW BOULVEARD OVERCROSSING TO 0.2 MILE EAST OF ALTA CANYADA ROAD OVERCROSSING
QA Service Level1 (Verified on 10/19/2023)

Sample Information

Sample Taken Date10/09/2024 Sample Unique Key51
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/11/2024
Sample typeVerification A brief description of the sampleJMF verification sample
The quantity of what the sample constitutes1can From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed byBassily
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
Modified Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2024-10-09-51
DIME Test ID: 2024-10-09-51-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2024-10-15

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Angelito Villegas
Date of test: 10/14/2024
Time of test: 11:05 HH:MM
Test Temperature: 135.0 C
Speed: 100 rpm
Spindle size: 21 in
Torque: 80.0 %
Viscosity reading #1 (A) : 0.397 Pa-s
Viscosity reading #2 (B) : 0.399 Pa-s
Viscosity reading #3 (C): 0.404 Pa-s
Average viscosity: 0.4 Pa-s
General comments (publicly viewable) (Max 1000 characters): For information purposes only

Test was verified on 10/15/2024