Summary for Test 2024-09-13-68-4
Test performed: AASHTO T269-14Project Information
Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
---|---|
DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
Award Date | 07/13/2023 |
Closeout Date | Not set |
Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 09/13/2024 | Sample Unique Key | 68 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2024 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 RHMA-G |
The quantity of what the sample constitutes | 0-750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Magana | Last name of sampler or witnessed by | Luis |
Title of sampler | Telephone number of sampler | 2092250104 | |
Laboratory sample identification | HW-090924-ACSE1 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan Materials-Pleasanton | Transportation Laboratory (TL) Number | C690435 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 1 |
Sublot number | 9 | HMA Mix Number | D04 JMF 24 035 |
Test Details
DIME Sample ID: 2024-09-13-68
DIME Test ID: 2024-09-13-68-4
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2024-10-14
Test Results
Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Luis Magana
Date of test: 09/19/2024
Percent Air Voids: 94 %
Percent Air Voids 2: 94.5 %
Percent Air Voids 3: 94.7 %
Average Percent Air Voids: 94.4 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/14/2024 ✔