Summary for Test 2017-05-03-8-1

Test performed: AGGLP SIEVE_ANALYSIS-1

Project Information

Project IdentifiersProject ID: 212150
DEA: 010G9004
EFIS: 0117000072
DIST-CO-RTE-PM01-MEN-162,16.2-0/16.2, 0/25.0, 0.0/25.0
Award Date02/03/2017
Closeout Date01/07/2021
Work DescriptionMEN-162 Storm Repairs
Location DescriptionIN MENDOCINO COUNTY NEAR LAYTONVILLE FROM JCT 101 TO 1.0 MILES EAST OF MID FORK EEL RIVER BR #10-0252.
QA Service Level1 (Verified on 06/08/2017)

Sample Information

Sample Taken Date05/03/2017 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing08/14/2017 Sample typeQuality Control
A brief description of the sampleSoil The quantity of what the sample constitutes1 bag
From where was the sample collectedJob Site First name of sampler or witnessed byTM
Last name of sampler or witnessed byLiao Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identification17SOIL-0247
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameNA
Transportation Laboratory (TL) NumberC836626 Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sampleUnknown
The fabricator/manufacturer designation for the sampleUnknown A detailed description of where the material sample was collectedRC-17-002-9
Where the material sample would have been placed if not sampled9 ft

Test Details

DIME Sample ID: 2017-05-03-8
DIME Test ID: 2017-05-03-8-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-08-23

Test Results


Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 08/23/2017
Total mass of material in the sample: 770.0 grams
Cumulative mass retained on the 2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 1 in. sieve: 0.0 grams
Cumulative mass retained on the 3/4 in. sieve: 40.0 grams
Cumulative mass retained on the 1/2 in. sieve: 0.0 grams
Cumulative mass retained on the 3/8 in. sieve: 2.0 grams
Cumulative mass retained on the #4 sieve: 40.0 grams
Cumulative mass retained on the #8 sieve: 14.0 grams
Total sample mass passing the #4 sieve: 689 grams
Total mass of fine material in the sample: 518 grams
Cumulative mass retained on the pan: 502.0 grams
Total cumulative mass of coarse aggregate: 82 grams
Total cumulative mass of fine aggregate: 516 grams
Sum of coarse and fine aggregate: 771 grams
Percentage of coarse material: 11 %
Percentage of fine material: 89 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 95 %
Cumulative percent passing the 1/2 in. sieve: 95 %
Cumulative percent passing the 3/8 in. sieve: 95 %
Cumulative percent passing the #4 sieve: 89 %
Cumulative percent passing the #8 sieve: 87 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/23/2017 ✔