Summary for Test 2024-10-01-91-1
Test performed: CTM 524-March 2013Project Information
| Project Identifiers | Project ID: 994744 DEA: 072XG504 EFIS: 0723000149 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-66.3/67.3 |
| Award Date | 03/27/2023 |
| Closeout Date | 09/26/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 05/04/2023) |
Sample Information
| Sample Taken Date | 10/01/2024 | Sample Unique Key | 91 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2024 |
| Sample type | Acceptance | A brief description of the sample | JPCP-RSC |
| The quantity of what the sample constitutes | 51 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Philip | Last name of sampler or witnessed by | Maquiran |
| Title of sampler | MREA | Telephone number of sampler | (213) 358-1518 |
| Laboratory sample identification | 24-3049 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Short Load Concrete | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | CTS-65-EHI |
|---|---|---|---|
| The truck number from where the sample was collected | 19 | The batch plant ticket number from where the sample was collected | 2 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | Truck Chute | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-10-01-91
DIME Test ID: 2024-10-01-91-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2024-10-13
Test Results
Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: Phillip Maquiran
Date of test: 10/11/2024
Identification number: 24-3049
Width of specimen: 5.9375 inch
Width of specimen 2: 5.9375 inch
Width of specimen 3: 6.0625 inch
Depth of specimen: 6.125 inch
Depth of specimen 2: 6.125 inch
Depth of specimen 3: 6.0625 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 9260 lb
Maximum load applied 2: 9222 lb
Maximum load applied 3: 9686 lb
Curing history and apparent moisture condition of the specimen: Damp
If specimen was capped, ground or if leather shims were used: No
Defects in specimen, including numbers of beams discarded during test: No
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 790 psi
Modulus of rupture 2: 780 psi
Modulus of rupture 3: 820 psi
Modulus of rupture average: 800 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/13/2024 ✔