Summary for Test 2024-08-29-31-1
Test performed: ASTM C39-10Project Information
| Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
| Award Date | 09/24/2021 |
| Closeout Date | 11/03/2025 |
| Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
| Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
| Sample Taken Date | 08/29/2024 | Sample Unique Key | 31 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/03/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 6X12 |
| The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Dominic | Last name of sampler or witnessed by | Montemayor |
| Title of sampler | QA Consultant | Telephone number of sampler | |
| Laboratory sample identification | 1042-A6 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | SULLY Miller | Transportation Laboratory (TL) Number | 1042-A6 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | G3-22-PCC-273 |
|---|---|---|---|
| The truck number from where the sample was collected | Not Provided on TL | The batch plant ticket number from where the sample was collected | 14 |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | SB LANE 1, 13' WIDE, STATION 270+75 - 270+90 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-08-29-31
DIME Test ID: 2024-08-29-31-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-10-11
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 10/10/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Average diameter of cylinder 3: 6.00 in
Maximum load on cylinder 1: 165440 lb
Maximum load on cylinder 2: 159810 lb
Maximum load on cylinder 3: 167285 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Cross sectional area of cylinder 3: 28.27 in^2
Compressive strength of cylinder 1: 5852.1 psi
Compressive strength of cylinder 2: 5653.0 psi
Compressive strength of cylinder 3: 5917.4 psi
Compressive strength (to nearest 10 psi): 5810 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/11/2024 ✔