Summary for Test 2024-09-05-112-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993527
DEA: 07327304
EFIS: 0716000126
DIST-CO-RTE-PM07-LA-103-0.1
Award Date04/21/2022
Closeout Date08/28/2026
Work DescriptionINSTALL PUMP PLANT EQUIPMENT AND DRAINAGE SYSTEM.
Location DescriptionTHE CITY AND COUNTY OF LOS ANGELES AT HENRY FORD AVENUE OFF-RAMP
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key112
Date that the sample was received by the laboratory/organization performing the testing09/06/2024 Sample typeAcceptance
A brief description of the sample4X8 PCC cylinders The quantity of what the sample constitutes130 CY
From where was the sample collectedJob Site First name of sampler or witnessed byLuis
Last name of sampler or witnessed byVargas Title of samplerStructure Representative
Telephone number of sampler Laboratory sample identification24-212
Linked DIME Sample ID The fabricator/manufacturer/facility nameA&A Ready Mixed Concrete
Transportation Laboratory (TL) Number09052024 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number557237SP
The truck number from where the sample was collected0909 The batch plant ticket number from where the sample was collected496785
Concrete batch plantAAA Ready Mix Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-09-05-112
DIME Test ID: 2024-09-05-112-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-11

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 10/03/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.02 in
Average diameter of cylinder 2: 4.02 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 60287 lb
Maximum load on cylinder 2: 59331 lb
Maximum load on cylinder 3: 63173 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.69 in^2
Cross sectional area of cylinder 2: 12.69 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 4750.7 psi
Compressive strength of cylinder 2: 4675.4 psi
Compressive strength of cylinder 3: 4978.2 psi
Compressive strength (to nearest 10 psi): 4800 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/11/2024 ✔