Summary for Test 2024-09-12-79-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994297
DEA: 07336804
EFIS: 0717000014
DIST-CO-RTE-PM07-LA-118-R4.5/R9.1
Award Date11/17/2022
Closeout DateNot set
Work DescriptionPLACE CONCRETE AND INSTALL RAILINGS.
Location DescriptionTHE CITY AND COUNTY OF LOS ANGELES FROM 0.1 MILE WEST OF TAMPA AVENUE TO WOODLEY AVENUE
QA Service Level1 (Verified on 10/06/2022)

Sample Information

Sample Taken Date09/12/2024 Sample Unique Key79
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2024
Sample typeAcceptance A brief description of the sample6X12 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byArian Last name of sampler or witnessed byAngha
Title of samplerAssistant Structure Representative Telephone number of sampler
Laboratory sample identification24-226 Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Ready Mix Transportation Laboratory (TL) NumberNA
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number556300
The truck number from where the sample was collected1 The batch plant ticket number from where the sample was collected844616
Concrete batch plantNational Ready Mix Concrete The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-09-12-79
DIME Test ID: 2024-09-12-79-1
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-11

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 09/19/2024
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Maximum load on cylinder 1: 66125 lb
Maximum load on cylinder 2: 67298 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength of cylinder 1: 2330.8 psi
Compressive strength of cylinder 2: 2372.2 psi
Compressive strength (to nearest 10 psi): 2350 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 10/11/2024