Summary for Test 2024-09-28-27-2
Test performed: CTM 202-November 2011Project Information
| Project Identifiers | Project ID: 994503 DEA: 042W0704 EFIS: 0421000133 MINOR: 04A6556 |
|---|---|
| DIST-CO-RTE-PM | 04-MRN-101- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 02/28/2023) |
Sample Information
| Sample Taken Date | 09/28/2024 | Sample Unique Key | 27 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/28/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2 x 3/8 PCC | The quantity of what the sample constitutes | 2 Bags sand + Rock |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | IGNACIO |
| Last name of sampler or witnessed by | ARECHIGA | Title of sampler | Lab Technician |
| Telephone number of sampler | 5102077252 | Laboratory sample identification | Rich_24_127 |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Shamrock /San Rafael | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 000000000000000 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant Stockpiles | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/8 inch | |
| The concrete mix design number | D67112E1 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-09-28-27
DIME Test ID: 2024-09-28-27-2
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-10-10
Test Results
What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 09/28/2024
| Sieve Size | Cumulative Percent Passing | |||||
|---|---|---|---|---|---|---|
| 100 % | ||||||
| 100 % | ||||||
| 82 % | ||||||
| 66 % | ||||||
| 47 % | ||||||
| 24 % | ||||||
| 7 % | ||||||
| 2 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/10/2024 ✔