Summary for Test 2024-10-02-89-3
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 0422825 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80-6.4/6.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Excavation, HMA, structural concrete, minor concrete and drainage. |
| Location Description | IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 10/02/2024 | Sample Unique Key | 89 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Class 2 Permeable Base |
| The quantity of what the sample constitutes | 3 bags | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
| Title of sampler | Lab Technician | Telephone number of sampler | 5102077252 |
| Laboratory sample identification | C290- | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Pleasanton | Transportation Laboratory (TL) Number | C290- |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpiles at the Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-10-02-89
DIME Test ID: 2024-10-02-89-3
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-10-10
Test Results
Number of tests: 1
Input Type: Measured
Tester's full name: IGNACIO ARECHIGA
Date of test: 10/02/2024
Temperature correction: 0
Temperature of solution: 72
Clay reading (test 1): 5.6
Sand reading (test 1): 4.1
Sand equivalent (test 1): 74
Sand equivalent before temperature correction: 74
Sand equivalent after temperature correction: 74
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/10/2024 ✔