Summary for Test 2024-08-12-115-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 993184 DEA: 040A7724 EFIS: 0420000288 COOP: 0422825 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-80-6.4/6.8 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Excavation, HMA, structural concrete, minor concrete and drainage. |
| Location Description | IN BERKELEY AND ALBANY FROM 0.6 MILE NORTH OF UNIVERSITY AVENUE OVERCROSSING TO 0.3 MILE SOUTH OF EL CERRITO SEPARATION AND OVERHEAD |
| QA Service Level | 1 (Verified on 04/08/2022) |
Sample Information
| Sample Taken Date | 08/12/2024 | Sample Unique Key | 115 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/12/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Hot Mix |
| The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
| Title of sampler | Plant Manager | Telephone number of sampler | 5102077252 |
| Laboratory sample identification | C290-8-12 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Dutra Richmond | Transportation Laboratory (TL) Number | C290-8-12 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | L240098 |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-08-12-115
DIME Test ID: 2024-08-12-115-1
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-10
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/12/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1559.1 g
Mass Loss: 100.0 g
Correction Factor (Percent by mass of HMA Specimen): 1.38 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.22 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.80 %
General comments (publicly viewable) (Max 1000 characters): Oil is low
Test was verified on 10/10/2024 ✔