Summary for Test 2024-10-01-77-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994469
DEA: 044J89U4
EFIS: 0419000140
COOP: 042806
DIST-CO-RTE-PM04-SCL-82-18.2/26.4
Award Date08/17/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, RHMA, SLAB REPL, CURB RAMPS, AND MOD ELECT SYSTEMS.
Location DescriptionSANTA CLARA COUNTY AT VARIOUS LOCATIONS FROM KNICKERBOCKER DRIVE IN SUNNYVALE TO SAN MATEO COUNTY LINE IN PALO ALTO
QA Service Level1 (Verified on 05/09/2023)

Sample Information

Sample Taken Date10/01/2024 Sample Unique Key77
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/02/2024
Sample typeQuality Assurance A brief description of the sample3/4" RHMA-G WMA
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byKevin Last name of sampler or witnessed byKoenig
Title of samplerQC Telephone number of sampler
Laboratory sample identificationSJ-100124-SA2 Linked DIME Sample ID
The fabricator/manufacturer/facility nameDeSilva Gates Aggregates Sunol Transportation Laboratory (TL) NumberC317-100124-2
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0007
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyer Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number6654 Lot number2
Sublot number10 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-10-01-77
DIME Test ID: 2024-10-01-77-1
Testing Lab: CT D04 - San Jose Construction Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-10-31

Test Results


What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Charles Poolis
Date of test: 10/31/2024
Cumulative Percent Passing
%
100 %
100 %
98 %
88 %
72 %
31 %
13 %
8 %
6 %
4 %
3 %
2.1 %
General comments (publicly viewable) (Max 1000 characters): DeSilva Gates Aggregates Sunol Drum Plant

Test was verified on 10/31/2024