Summary for Test 2024-09-05-106-2

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994235
DEA: 030J8704
EFIS: 0320000035
DIST-CO-RTE-PM03-BUT-191-8.4/10.1
Award Date12/28/2022
Closeout DateNot set
Work DescriptionSTABILIZE CUT SLOPE, WIDEN SHOULDERS, REPLACE DRAINAGE AND PLACE HMA.
Location DescriptionBUTTE COUNTY IN AND NEAR PARADISE FROM 0.3 MILES SOUTH OF AIRPORT ROAD TO 0.2 MILES NORTH OF OLD CLARK ROAD
QA Service Level1 (Verified on 09/14/2022)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key106
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/07/2024
Sample typeProduction Start-Up A brief description of the sample12 Boxes
The quantity of what the sample constitutes3/4" HMA w/ 15% RAP From where was the sample collectedSource
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMckeehan
Title of samplerTET Telephone number of sampler
Laboratory sample identificationDaily 24-233 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Hallwood Transportation Laboratory (TL) NumberC802855
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number3
Sublot number1 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-05-106
DIME Test ID: 2024-09-05-106-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-10

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Joshua Wilson
Date of test: 10/09/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2162.8 g
Mass Loss: 113.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.51 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.71 %
General comments (publicly viewable) (Max 1000 characters): R1 OBC 4.7

Test was verified on 10/10/2024