Summary for Test 2017-08-16-3-1
Test performed: ASTM A370-15Project Information
| Project Identifiers | Project ID: 210618 DEA: 06342534 EFIS: 0600000382 COOP: 061616A2 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-180-R74.1/R78.6 |
| Award Date | 04/05/2017 |
| Closeout Date | 07/06/2021 |
| Work Description | CONSTRUCT SEGMENT 3 OF KINGS CANYON EXPRESSWAY |
| Location Description | FRESNO COUNTY ABOUT 8.4 MILES EAST OF FRESNO FROM 0.7 MILE WEST OF SMITH AVENUE TO 0.7 MILE EAST OF FRANKWOOD AVENUE |
| QA Service Level | 1 (Verified on 07/10/2017) |
Sample Information
| Sample Taken Date | 08/16/2017 | Sample Unique Key | 3 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2017 |
| Sample type | Quality Assurance | A brief description of the sample | 2 Ductile Iron Casting |
| The quantity of what the sample constitutes | 2 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Dywidag Systems | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 2087 |
|---|---|---|---|
| Part Number (s) | 68 31 216 246 | Material Specification | A536 |
| Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Golden Foundary Machine Co |
| Prestressing Manufacturer | Dywidag Systems |
Test Details
DIME Sample ID: 2017-08-16-3
DIME Test ID: 2017-08-16-3-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2017-08-29
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: Fred
Date of test: 08/22/2017
UTM: 67KIP
Temperature: 72 F
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 2067 | 0.497 | 0.194 | 44797 | 72360 | 20 | Fred | |
| 2 | 2067 | 0.497 | 0.194 | 44597 | 72000 | 20.2 | Fred |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 8/22/2017 ✔