Summary for Test 2024-09-30-60-2

Test performed: AASHTO T275-07r12

Project Information

Project IdentifiersProject ID: 1000233
DEA: 09398004
EFIS: 0923000027
DIST-CO-RTE-PM09-KER-58-R93.0/R97.0,R139.8
Award Date05/24/2024
Closeout Date12/02/2024
Work DescriptionHOT MIX ASPHALT (TYPE A), & REMOVE CONCRETE PAVEMENT.
Location DescriptionKERN COUNTY NEAR TEHACHAPI FROM 0.2 MILE EAST OF DENNISON ROAD OVERCROSSING TO 2.2 MILES WEST OF SAND CANYON OVERHEAD BRIDGE AND NEAR BORON AT BORAX ROAD OVERCROSSING
QA Service Level1 (Verified on 04/03/2024)

Sample Information

Sample Taken Date09/30/2024 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/03/2024
Sample typeAcceptance A brief description of the sample3/4" HMA-A-SP PG64-16 R25
The quantity of what the sample constitutesProduction Start Up From where was the sample collectedSource
First name of sampler or witnessed byGranite Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identificationPSU-1 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite Solari Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-30-60
DIME Test ID: 2024-09-30-60-2
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2024-10-08

Test Results


Number of tests: 3
What test procedure is performed?: Method A
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 10/07/2024
Bulk Specific Gravity: 2.458
Bulk Specific Gravity 2: 2.448
Bulk Specific Gravity 3: 2.454
Average Bulk Specific Gravity: 2.453
General comments (publicly viewable) (Max 1000 characters): PSU-01 HMA

Test was verified on 10/8/2024