Summary for Test 2024-09-30-25-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 993141 DEA: 060V1204 EFIS: 0616000207 |
|---|---|
| DIST-CO-RTE-PM | 06-MAD-99-R6.9/R7.6 |
| Award Date | 06/22/2022 |
| Closeout Date | 12/02/2025 |
| Work Description | Cottonwood Creek Bridge Replacement - REPLACE BRIDGES AND CONSTRUCT RETAINING WALLS. |
| Location Description | MADERA COUNTY NEAR MADERA FROM 0.4 MILE SOUTH OF COTTONWOOD CREEK BRIDGE TO 0.1 MILE NORTH OF AVENUE 12 OVERCROSSING |
| QA Service Level | 1 (Verified on 07/28/2021) |
Sample Information
| Sample Taken Date | 09/30/2024 | Sample Unique Key | 25 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/01/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Compressive Strength samples |
| The quantity of what the sample constitutes | 97.5 CY | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Juan | Last name of sampler or witnessed by | De La Torre |
| Title of sampler | ASR | Telephone number of sampler | 559-363-0082 |
| Laboratory sample identification | 200 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Builders Concrete | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Retaining wall 1 | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | ND10531 |
|---|---|---|---|
| The truck number from where the sample was collected | 9116 | The batch plant ticket number from where the sample was collected | 1364194 |
| Concrete batch plant | Builders Sanger | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | TAIL GATE | Where the material sample would have been placed if not sampled | RW 1 stem sta10+79 to sta 11+75 |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-09-30-25
DIME Test ID: 2024-09-30-25-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-10-08
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Gurjeet Litt
Date of test: 10/08/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 36420 lb
Maximum load on cylinder 2: 37770 lb
Maximum load on cylinder 3: 35650 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 8 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 2897.4 psi
Compressive strength of cylinder 2: 3004.8 psi
Compressive strength of cylinder 3: 2836.1 psi
Compressive strength (to nearest 10 psi): 2910 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/8/2024 ✔