Summary for Test 2024-09-21-8-3
Test performed: ASTM D638-Dec14Project Information
| Project Identifiers | Project ID: 1000578 DEA: 112N1704 EFIS: 1122000283 |
|---|---|
| DIST-CO-RTE-PM | 11-SD-805-15.72-28.3 |
| Award Date | 05/20/2024 |
| Closeout Date | 06/09/2025 |
| Work Description | Bridge Preservation |
| Location Description | In San Diego at various locations from Landis Street Overcrossing to Sorrento Valley Boulevard Undercrossing |
| QA Service Level | 1 (Verified on 09/03/2024) |
Sample Information
| Sample Taken Date | 09/21/2024 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/24/2024 | Sample type | Quality Control |
| A brief description of the sample | 1 gallon can / PPC 1121 RESIN | The quantity of what the sample constitutes | 2 tankers |
| From where was the sample collected | Source | First name of sampler or witnessed by | Gilberto |
| Last name of sampler or witnessed by | Gonzalez | Title of sampler | Quality Control Manager |
| Telephone number of sampler | 7076245467 | Laboratory sample identification | 000129KBP |
| Linked DIME Sample ID | 000129KBP | The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia |
| Transportation Laboratory (TL) Number | Sacramento Caltrans lab | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Polyester | Mfg. Lot Number(s) | AZ4I01480 |
|---|---|---|---|
| Batch Number | AZ4I01480 | Mix number | AZ4I01480 |
Test Details
DIME Sample ID: 2024-09-21-8
DIME Test ID: 2024-09-21-8-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM D638-Dec14: Standard Test Method for Tensile Properties of Plastics
Test Release Date: 2024-10-07
Test Results
Number of specimens tested: 6
Input Type: Measured
Tester's full name: Linda Bergstrom
Date of test: 09/26/2024
Conditioning procedure: 18/25/50+5/70
Speed of testing: 0.45 in/min
Sample 1 Width: 0.487 in
Sample 1 Thickness: 0.255 in
Sample 1 Area: 0.1242 in^2
Sample 1 Ultimate Strength Actual: 365.521 lbs
Sample 1 percent elongation: 74.1 %
Sample 1 Time: 0 MM:SS
Sample 2 Width: 0.486 in
Sample 2 Thickness: 0.259 in
Sample 2 Area: 0.1259 in^2
Sample 2 Ultimate Strength Actual: 332.502 lbs
Sample 2 percent elongation: 64.9 %
Sample 2 Time: 0 MM:SS
Sample 3 Width: 0.485 in
Sample 3 Thickness: 0.258 in
Sample 3 Area: 0.1251 in^2
Sample 3 Ultimate Strength Actual: 303.493 lbs
Sample 3 percent elongation: 55 %
Sample 3 Time: 0 MM:SS
Sample 4 Width: 0.486 in
Sample 4 Thickness: 0.261 in
Sample 4 Area: 0.1268 in^2
Sample 4 Ultimate Strength Actual: 359.478 lbs
Sample 4 percent elongation: 72.8 %
Sample 4 Time: 0 MM:SS
Sample 5 Width: 0.486 in
Sample 5 Thickness: 0.259 in
Sample 5 Area: 0.1259 in^2
Sample 5 Ultimate Strength Actual: 328.095 lbs
Sample 5 percent elongation: 64.3 %
Sample 5 Time: 0 MM:SS
Sample 6 Width: 0.486 in
Sample 6 Thickness: 0.253 in
Sample 6 Area: 0.123 in^2
Sample 6 Ultimate Strength Actual: 342.432 lbs
Sample 6 percent elongation: 69.8 %
Sample 6 Time: 0 MM:SS
Sample 1 Ultimate strength: 2943 psi
Sample 2 Ultimate strength : 2641 psi
Sample 3 Ultimate strength: 2426 psi
Sample 4 Ultimate strength: 2835 psi
Sample 5 Ultimate strength: 2606 psi
Sample 6 Ultimate strength : 2784 psi
Ultimate Strength Average: 2706 psi
Percent Elongation Average: 67 %
General comments (publicly viewable) (Max 1000 characters): Accepted Vendor's Results
Test was verified on 10/7/2024 ✔