Summary for Test 2024-09-09-37-1
Test performed: ASTM C39-21Project Information
| Project Identifiers | Project ID: 212470 DEA: 044A1304 EFIS: 0400001106 COOP: 042718 |
|---|---|
| DIST-CO-RTE-PM | 04-SON-101-18.5/18.5 |
| Award Date | 11/17/2023 |
| Closeout Date | Not set |
| Work Description | CONSISTS OF MODIFICATION AND RECONSTRUCTION OF THE EXISTING US 101/HEARN AVENUE INTERCHANGE IN SONOMA COUNTY, INCLUDING REPLACING THE EXISTING TWO-LANE HEARN AVENUE OVERCROSSING WITH A NEW OVERCROSSING, AND MODIFYING THE SOUTHBOUND OFF-RAMP IN CITY |
| Location Description | IN SONOMA COUNTY. |
| QA Service Level | 1 (Verified on 09/23/2019) |
Sample Information
| Sample Taken Date | 09/09/2024 | Sample Unique Key | 37 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/13/2024 |
| Sample type | Quality Control | A brief description of the sample | Concrete Cylinders 4x8 |
| The quantity of what the sample constitutes | 13 yd³ | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Keith | Last name of sampler or witnessed by | Iwamoto |
| Title of sampler | ASR | Telephone number of sampler | 5108676764 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Supperior Supplies, Inc | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Wall 202B | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 590CR2 |
|---|---|---|---|
| The truck number from where the sample was collected | 65 | The batch plant ticket number from where the sample was collected | 306071 |
| Concrete batch plant | Superior Supplies Santa Rosa | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Truck Chute | Where the material sample would have been placed if not sampled | Retaining Wall Stem |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2024-09-09-37
DIME Test ID: 2024-09-09-37-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-10-07
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 10/07/2024
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: no data
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 71561 lbf
Maximum load on cylinder 2: 73347 lbf
Maximum load on cylinder 3: 75754 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 5666.0 psi
Compressive strength of cylinder 2: 5808.0 psi
Compressive strength of cylinder 3: 5998 psi
Compressive strength (to nearest 10 psi): 5820 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3
Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3
Test was verified on 10/7/2024 ✔