Summary for Test 2024-09-12-37-1
Test performed: CONCLP 4-16Project Information
| Project Identifiers | Project ID: 1000267 DEA: 070W6404 EFIS: 0722000357 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-2,134,170-Var |
| Award Date | 06/24/2024 |
| Closeout Date | 07/24/2025 |
| Work Description | METHACRYLATE, POLYESTER OVERLAY, SPILL REPAIR AND JOINT SEALS. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 09/16/2024) |
Sample Information
| Sample Taken Date | 09/12/2024 | Sample Unique Key | 37 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/12/2024 | Sample type | Quality Control |
| A brief description of the sample | 2 pints 204, CHP, 8020 | The quantity of what the sample constitutes | 100 Totes |
| From where was the sample collected | Source | First name of sampler or witnessed by | Gilberto |
| Last name of sampler or witnessed by | Gonzalez | Title of sampler | Quality Control Manager |
| Telephone number of sampler | 7076245467 | Laboratory sample identification | 000123KBP |
| Linked DIME Sample ID | 000123KBP | The fabricator/manufacturer/facility name | Kwik Bond Polymers, Benicia |
| Transportation Laboratory (TL) Number | Sacramento Caltrans lab | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Methacrylate | Mfg. Lot Number(s) | 24-90-191290 |
|---|---|---|---|
| Batch Number | 2490191290 | Mix number | 2490191290 |
Test Details
DIME Sample ID: 2024-09-12-37
DIME Test ID: 2024-09-12-37-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-10-04
Test Results
Input Type: Calculated
Tester's full name: Rachael Chavez
Date of test: 10/03/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 24.5
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 8.2
Flash point (ASTM D 3828) more than 180 deg F: 180
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 725
Tack free time, 400 minutes max: 358
General comments (publicly viewable) (Max 1000 characters): Tack free time accepted using vendor's results.
Test was verified on 10/4/2024 ✔