Summary for Test 2024-09-05-92-3

Test performed: ASTM C39-21

Project Information

Project IdentifiersProject ID: 994378
DEA: 040K6304
EFIS: 0416000111
DIST-CO-RTE-PM04-NAP-29-16.4/19.0
Award Date06/27/2023
Closeout DateNot set
Work DescriptionBRIDGE RAIL REPLACEMENT AND SHOULDER WIDENING.
Location DescriptionNAPA COUNTY NEAR YOUNTVILLE AT VARIOUS LOCATIONS FROM 0.1 MILE SOUTH OF DRY CREEK BRIDGE TO 0.1 MILE NORTH OF CALIFORNIA DRIVE UNDERCROSSIG
QA Service Level1 (Verified on 10/27/2022)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key92
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing09/23/2024
Sample typeQuality Assurance A brief description of the sampleculvert footing (invert bottom) and type 7B wall footing
The quantity of what the sample constitutes3 From where was the sample collectedJob Site
First name of sampler or witnessed byANGELO Last name of sampler or witnessed byPerez
Title of sampler Telephone number of sampler5103939319
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNorthgate Ready Mix Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure namePerfume Creek Bridge Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design number3B6386
The truck number from where the sample was collected5681048 The batch plant ticket number from where the sample was collected81201626
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedwheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2024-09-05-92
DIME Test ID: 2024-09-05-92-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2024-10-03

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 10/03/2024
Capped in accordance with?: no data
Apparent mass of submerged cylinder 1: no data
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.01 in
Average diameter of cylinder 3: 4.01 in
Maximum load on cylinder 1: 52355 lbf
Maximum load on cylinder 2: 54555 lbf
Maximum load on cylinder 3: 54019 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.63 in^2
Cross sectional area of cylinder 3: 12.63 in^2
Compressive strength of cylinder 1: 4146.0 psi
Compressive strength of cylinder 2: 4320.0 psi
Compressive strength of cylinder 3: 4277 psi
Compressive strength (to nearest 10 psi): 4250 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for Cylinder Code 1 of 3

Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 3

Source: Bluehill Data Point File
Test graph for Cylinder Code 3 of 3

Test was verified on 10/3/2024