Summary for Test 2024-09-30-27-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993318
DEA: 11423704
EFIS: 1116000059
DIST-CO-RTE-PM11-SD-8-R31.8/R41.7
Award Date04/01/2022
Closeout Date04/08/2025
Work DescriptionPLACE CRCP, HMA, MGS, AND WATER POLLUTION CONTROL SYSTEM.
Location DescriptionSAN DIEGO COUNTY NEAR ALPINE FROM VIEJAS CREEK BRIDGE TO PINE VALLEY CREEK BRIDGE
QA Service Level1 (Verified on 10/27/2021)

Sample Information

Sample Taken Date09/30/2024 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/01/2024
Sample typeQuality Assurance A brief description of the samplePSU
The quantity of what the sample constitutes12 boxes From where was the sample collectedSource
First name of sampler or witnessed byJesse Last name of sampler or witnessed byGastelum
Title of sampler Telephone number of sampler7605628612
Laboratory sample identification65109-PSU Linked DIME Sample ID2024-09-30-28
The fabricator/manufacturer/facility nameMartin Marietta Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number21217105
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-30-27
DIME Test ID: 2024-09-30-27-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-10-02

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 10/02/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3960.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5501.5 g
Mass of HMA Sample prior to ignition: 1540.6 g
Mass Loss: 85.2 g
Mass of aggregate remaining after ignition: 1455.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.13 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.40 %
General comments (publicly viewable) (Max 1000 characters): Complies - Target 5.25% Tested 5.40%

Test was verified on 10/2/2024