Summary for Test 2024-10-01-9-1
Test performed: AASHTO T27-14Project Information
| Project Identifiers | Project ID: 1000007 DEA: 061F8304 EFIS: 0623000101 |
|---|---|
| DIST-CO-RTE-PM | 06-FRE-180-43.5/53.6 |
| Award Date | 06/11/2024 |
| Closeout Date | 10/31/2025 |
| Work Description | COLD PLANE AC PAVEMENT, RHMA-G (BWC) AND HMA (TYPE A). |
| Location Description | FRESNO COUNTY NEAR KERMAN FROM GOLDENROD AVENUE TO BRAWLEY AVENUE |
| QA Service Level | 1 (Verified on 01/08/2024) |
Sample Information
| Sample Taken Date | 10/01/2024 | Sample Unique Key | 9 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/02/2024 | Sample type | Quality Assurance |
| A brief description of the sample | 1/2” RHMA Aggregate | The quantity of what the sample constitutes | 0-750 Tons Produced |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Noah |
| Last name of sampler or witnessed by | Hunt | Title of sampler | Senior Materials Tester |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Vulcan Madera Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-20-0016 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Automatic Sampling Device @ Plant | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | 2 | |
| Sublot number | 8 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-10-01-9
DIME Test ID: 2024-10-01-9-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2024-10-02
Test Results
What type of gradation is being tested?: HMA Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: No
Input Type: Calculated
Tester's full name: Tomas Silva
Date of test: 10/01/2024
| Cumulative Percent Passing | ||||||
|---|---|---|---|---|---|---|
| % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 100 % | ||||||
| 97 % | ||||||
| 85 % | ||||||
| 46 % | ||||||
| 21 % | ||||||
| 15 % | ||||||
| 12 % | ||||||
| 8 % | ||||||
| 4 % | ||||||
| 1.8 % | ||||||
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/2/2024 ✔