Summary for Test 2024-09-24-86-2

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 1000250
DEA: 040Y3904
EFIS: 0422000274
DIST-CO-RTE-PM04-ALA-262-R0.0/R1.1
Award Date06/10/2024
Closeout Date09/05/2025
Work DescriptionCOLD PLANE AC PAVEMENT AND PLACE RHMA-G.
Location DescriptionALAMEDA COUNTY IN FREMONT FROM ROUTE 880 TO ROUTE 680
QA Service Level1 (Verified on 06/03/2024)

Sample Information

Sample Taken Date09/24/2024 Sample Unique Key86
Date that the sample was received by the laboratory/organization performing the testing09/25/2024 Sample typeProduction Start-Up
A brief description of the sample1/2 RHMA-G The quantity of what the sample constitutes750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byMagana
Last name of sampler or witnessed byLuis Title of sampler
Telephone number of sampler2092250104 Laboratory sample identificationHW-092424-SASE
Linked DIME Sample ID The fabricator/manufacturer/facility nameMartin Marietta-Sunol Plant
Transportation Laboratory (TL) NumberC690436 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant Sampler
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2024-09-24-86
DIME Test ID: 2024-09-24-86-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-10-02

Test Results


How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Henry Concepcion
Date of test: 09/25/2024
Clay Level (Test 1): 7
Sand Level (Test 1): 3.5
Clay Level (Test 2): 7.6
Sand Level (Test 2): 3.8
Clay Level (Test 3): 7.8
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 50
Sand Equivalent (Test 2): 50
Sand Equivalent (Test 3): 49
Sand Equivalent: 50
General comments (publicly viewable) (Max 1000 characters): Test passed

Test was verified on 10/2/2024 ✔