Summary for Test 2024-09-24-86-2
Test performed: AASHTO T176-08Project Information
| Project Identifiers | Project ID: 1000250 DEA: 040Y3904 EFIS: 0422000274 |
|---|---|
| DIST-CO-RTE-PM | 04-ALA-262-R0.0/R1.1 |
| Award Date | 06/10/2024 |
| Closeout Date | 09/05/2025 |
| Work Description | COLD PLANE AC PAVEMENT AND PLACE RHMA-G. |
| Location Description | ALAMEDA COUNTY IN FREMONT FROM ROUTE 880 TO ROUTE 680 |
| QA Service Level | 1 (Verified on 06/03/2024) |
Sample Information
| Sample Taken Date | 09/24/2024 | Sample Unique Key | 86 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 09/25/2024 | Sample type | Production Start-Up |
| A brief description of the sample | 1/2 RHMA-G | The quantity of what the sample constitutes | 750 Tons |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | Magana |
| Last name of sampler or witnessed by | Luis | Title of sampler | |
| Telephone number of sampler | 2092250104 | Laboratory sample identification | HW-092424-SASE |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Martin Marietta-Sunol Plant | |
| Transportation Laboratory (TL) Number | C690436 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-01-0010 |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Plant Sampler | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1/2 inch | |
| The concrete mix design number | Lot number | 1 | |
| Sublot number | 1 | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-09-24-86
DIME Test ID: 2024-09-24-86-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2024-10-02
Test Results
How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Henry Concepcion
Date of test: 09/25/2024
Clay Level (Test 1): 7
Sand Level (Test 1): 3.5
Clay Level (Test 2): 7.6
Sand Level (Test 2): 3.8
Clay Level (Test 3): 7.8
Sand Level (Test 3): 3.8
Sand Equivalent (Test 1): 50
Sand Equivalent (Test 2): 50
Sand Equivalent (Test 3): 49
Sand Equivalent: 50
General comments (publicly viewable) (Max 1000 characters): Test passed
Test was verified on 10/2/2024 ✔