Summary for Test 2024-09-18-1-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 210485 DEA: 080R8504 EFIS: 0812000200 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-- |
| Award Date | 11/08/2023 |
| Closeout Date | 05/05/2025 |
| Work Description | CONSTRUCT SAND STORAGE BUILDING AND PAVE YARD |
| Location Description | SAN BERNARDINO COUNTY AT NIPTON 94200 CLARKE MOUNTAIN ROAD ON ROUTE 15 ABOUT 33 MILES EAST OF BAKER AT THE MOUNTAIN PASS MAINTENANCE STATION MOUNTAIN PASS, CALIFORNIA 92366 |
| QA Service Level | 1 (Verified on 06/24/2021) |
Sample Information
| Sample Taken Date | 09/18/2024 | Sample Unique Key | 1 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/24/2024 |
| Sample type | Quality Assurance | A brief description of the sample | 5/8 x 1 1/2" A325 Fastener Assembly |
| The quantity of what the sample constitutes | 15 assemblies | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Jacob | Last name of sampler or witnessed by | Garcia |
| Title of sampler | Telephone number of sampler | 3109128014 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cordova Bolt Inc. | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | L169-062-24 | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Bolt-1000220016 Nut-1000119836 Washer- 42331210 | Nut Mfg. Lot Number(s) | W000083965 |
| Washer Mfg. Lot Number(s) | 0923-854 | Bolt Specification | ASTM A325 |
| Bolt Length(s) | 1-1/2" | Nut Specification | ASTM A563 |
| Washer Specification | ASTM F436 | Finish | HDG ASTM F2329/A153 |
| Diameter/Size | 5/8" | Bolt Mfg. Lot Number | W000065570 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2024-09-18-1
DIME Test ID: 2024-09-18-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-10-01
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 10/01/2024
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 34846 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 10/1/2024 ✔