Summary for Test 2024-09-25-32-6

Test performed: AASHTO T324-14

Project Information

Project IdentifiersProject ID: 995450
DEA: 09368004
EFIS: 0917000011
DIST-CO-RTE-PM09-MNO-395-91.6/93.4
Award Date02/29/2024
Closeout Date04/03/2026
Work DescriptionHOT MIX ASPHALT (TYPE A), RAIL ELEMENT WALL, AND ROADWAY EXCAVATION.
Location DescriptionMONO COUNTY ABOUT 16 MILES NORTH OF BRIDGEPORT FROM BURCHAM FLAT ROAD TO 0.3 MILE SOUTH OF ROUTE 108
QA Service Level1 (Verified on 01/18/2024)

Sample Information

Sample Taken Date09/25/2024 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing09/25/2024 Sample typeAcceptance
A brief description of the sample3/4" HMA The quantity of what the sample constitutes24 boxes - 10,000 ton Milestone
From where was the sample collectedSupplier First name of sampler or witnessed byJeff
Last name of sampler or witnessed byPuente Title of samplerQA
Telephone number of sampler Laboratory sample identificationHMA 16
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Lee Vining
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure nameHwy 395 / Sonora Junction
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number13766
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-09-25-32
DIME Test ID: 2024-09-25-32-6
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2024-09-27

Test Results


Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 09/27/2024
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: 10000
Impression at specified number of passes average: 20 mm
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 10000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 10000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 4.29 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 4.45 mm
Stripping Inflection Point (Wheel A): 0
Stripping Inflection Point (Wheel B): 0
General comments (publicly viewable) (Max 1000 characters): HMA-16. Sample Passes

Test was verified on 9/27/2024 ✔