Summary for Test 2024-09-10-19-3
Test performed: CTM 301-March 2000Project Information
| Project Identifiers | Project ID: 215342 DEA: 07337804 EFIS: 0717000054 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-101,10,101,105-SO/R17.1 |
| Award Date | 09/15/2022 |
| Closeout Date | 08/20/2025 |
| Work Description | ROADSIDE SAFETY IMPROVEMENT |
| Location Description | LOS ANGELES COUNTY IN LOS ANGELES AT VARIOUS LOCATIONS |
| QA Service Level | 1 (Verified on 11/23/2020) |
Sample Information
| Sample Taken Date | 09/10/2024 | Sample Unique Key | 19 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 09/17/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Two 5-Gallon buckets of 3/4" CLASS III AB |
| The quantity of what the sample constitutes | 74 CY | From where was the sample collected | Supplier |
| First name of sampler or witnessed by | Christian | Last name of sampler or witnessed by | Mendoza |
| Title of sampler | Telephone number of sampler | (909) 538-1822 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cemex Moorpark Quarry #4425 | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-56-0014, Cemex Moorpark Quarry |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | 1307923-3/4" RECYCLED BASE | The fabricator/manufacturer designation for the sample | |
| The plant number | 4425 | A detailed description of where the material sample was collected | Stockpile at Cemex - Moorpark |
| Where the material sample would have been placed if not sampled | Maintenance Vehicle Pullout | Primary Aggregate Nominal Size | 3/4 inch |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-09-10-19
DIME Test ID: 2024-09-10-19-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 301-March 2000: Method for Determining the Resistance "R" Value of Treated and Untreated Bases, Subbases, and Basement Soils by the Stabilometer
Test Release Date: 2024-09-26
Test Results
How will the R value be determined?: By stabilometer
Input Type: Calculated
Tester's full name: Tess Perez
Date of test: 09/21/2024
As Received Gradation, Percent Passing 3 in. sieve: 100 %
As Received Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Received Gradation, Percent Passing 1 in. sieve: 100 %
As Received Gradation, Percent Passing 3/4 in. sieve: 99 %
As Received Gradation, Percent Passing 1/2 in. sieve: 84 %
As Received Gradation, Percent Passing 3/8 in. sieve: 73 %
As Received Gradation, Percent Passing #4 sieve: 48 %
As Received Gradation, Percent Passing #8 sieve: 36 %
As Received Gradation, Percent Passing #16 sieve: 27 %
As Received Gradation, Percent Passing #30 sieve: 20 %
As Received Gradation, Percent Passing #50 sieve: 13 %
As Received Gradation, Percent Passing #100 sieve: 9 %
As Received Gradation, Percent Passing #200 sieve: 7 %
As Used Gradation, Percent Passing 3 in. sieve: 100 %
As Used Gradation, Percent Passing 2 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 1/2 in. sieve: 100 %
As Used Gradation, Percent Passing 1 in. sieve: 100 %
As Used Gradation, Percent Passing 3/4 in. sieve: 100 %
As Used Gradation, Percent Passing 1/2 in. sieve: 85 %
As Used Gradation, Percent Passing 3/8 in. sieve: 74 %
As Used Gradation, Percent Passing #4 sieve: 48 %
As Used Gradation, Percent Passing #8 sieve: 36 %
As Used Gradation, Percent Passing #16 sieve: 27 %
As Used Gradation, Percent Passing #30 sieve: 20 %
As Used Gradation, Percent Passing #50 sieve: 13 %
As Used Gradation, Percent Passing #100 sieve: 9 %
As Used Gradation, Percent Passing #200 sieve: 7 %
R value: 80
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/26/2024 ✔