Summary for Test 2024-08-29-60-2
Test performed: CTM 204-June 2010Project Information
| Project Identifiers | Project ID: 994319 DEA: 023J7104 EFIS: 0222000076 |
|---|---|
| DIST-CO-RTE-PM | 02-PLU-89-8.7/12.9 |
| Award Date | 11/29/2022 |
| Closeout Date | 04/21/2025 |
| Work Description | PLACE HOT MIX ASPHALT (TYPE A) AND REPLACE AC SURFACING. |
| Location Description | PLUMAS COUNTY NEAR CRESCENT MILLS FROM ROUTE 70 TO 0.7 MILE SOUTH OF DIXIE CANYON ROAD |
| QA Service Level | 1 (Verified on 10/26/2022) |
Sample Information
| Sample Taken Date | 08/29/2024 | Sample Unique Key | 60 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/03/2024 |
| Sample type | Acceptance | A brief description of the sample | Shoulder Backing |
| The quantity of what the sample constitutes | 2 bags | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | CGI | Last name of sampler or witnessed by | CGI |
| Title of sampler | QC | Telephone number of sampler | |
| Laboratory sample identification | D79702 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Dig It Construction – Sierra Cascade Aggregate and Asphalt Products (Chester, CA) | Transportation Laboratory (TL) Number | 857951 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Sierra Cascade "Dig It" |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
| The plant number | A detailed description of where the material sample was collected | Stockpile | |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | Lot number | ||
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-08-29-60
DIME Test ID: 2024-08-29-60-2
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 204-June 2010: Method of Test for Liquid Limit, Plastic Limit and Plasticity Index of Soils (Plasticity Index)
Test Release Date: 2024-09-26
Test Results
The test method used?: Plastic Index
Input Type: Measured
Tester's full name: Josh Ferency
Date of test: 09/23/2024
Liquid Limit (LL): Undetermined %
Plastic Limit (PL): Undetermined %
Plastic Index(PI): NP
General comments (publicly viewable) (Max 1000 characters): LL=NP, PL=NP, PI=NP
Test was verified on 9/26/2024 ✔