Summary for Test 2024-09-09-84-5

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995443
DEA: 024J9104
EFIS: 0223000086
DIST-CO-RTE-PM02-TRI-299-30.2/36.9
Award Date04/02/2024
Closeout Date11/27/2024
Work DescriptionPLACE RUBBERIZED HOT MIX ASPHALT (GAP GRADED).
Location DescriptionTRINITY COUNTY NEAR BIG FLAT FROM 0.6 MILE EAST OF SKUNK POINT CAMPGROUND TO NORTH FORK TRINITY RIVER BRIDGE
QA Service Level1 (Verified on 11/27/2023)

Sample Information

Sample Taken Date09/09/2024 Sample Unique Key84
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/09/2024
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 1/2-inch RHMA-G (PG 64-16 CR)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byTerry Last name of sampler or witnessed byMcCormick
Title of samplerConsultant Telephone number of sampler
Laboratory sample identificationD79710 Linked DIME Sample ID
The fabricator/manufacturer/facility nameJ.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) Transportation Laboratory (TL) Number858024
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number
Binder content (%)7.5 Virgin binder PG PG 64-16
Design binder PG Binder SupplierValero (Benicia, CA)
RAP content (%)0 WMA Additives
Antistrip type1.0% Lime

Test Details

DIME Sample ID: 2024-09-09-84
DIME Test ID: 2024-09-09-84-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-25

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Sean Mcwithey
Date of test: 09/17/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 3112.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 4660.9 g
Mass of HMA Sample prior to ignition: 1548.7 g
Mass Loss: 117.2 g
Mass of aggregate remaining after ignition: 1431.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.07 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.31 %
General comments (publicly viewable) (Max 1000 characters): Pb=7.30

Test was verified on 9/25/2024