Summary for Test 2024-08-21-60-1
Test performed: ASTM A370-20Project Information
| Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
|---|---|
| DIST-CO-RTE-PM | 59--- |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 08/21/2024 | Sample Unique Key | 60 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/22/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Ductile Iron Casting |
| The quantity of what the sample constitutes | 12 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Daniel | Last name of sampler or witnessed by | Bishikwabo |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | SDI | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | B023 B074 C064 C064 H312 I012 I222 J192 J202 |
|---|---|---|---|
| Part Number (s) | ACS 31 6 AH SDI 19 6 AH SDI 12 6 PC BP SDI 19 | Material Specification | A536 |
| Grades | 80-55-06 | Metal Foundry Manufacturer (Mill) | Farrar Corporation |
| Prestressing Manufacturer | SDI |
Test Details
DIME Sample ID: 2024-08-21-60
DIME Test ID: 2024-08-21-60-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2024-10-14
Test Results
Number of Samples: 12
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 09/24/2024
UTM: 67kip
Temperature: 72 F
| Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | J272 | 0.5 | 0.19635 | 64913 | 114889 | 8.5 | aauvinen | |
| 2 | B023 | 0.5 | 0.19635 | 62671 | 109529 | 10.6 | rmacias | |
| 3 | I012 | 0.5 | 0.19635 | 61628 | 106988 | 9.4 | aauvinen | |
| 4 | C064 | 0.5 | 0.19635 | 63577 | 111284 | 9.7 | aauvinen | |
| 5 | I222 | 0.499 | 0.19556 | 62065 | 109405 | 9.8 | aauvinen | |
| 6 | B074 | 0.5 | 0.19635 | 61858 | 107954 | 8.9 | aauvinen | |
| 7 | C064 | 0.5 | 0.19635 | 64588 | 112109 | 7.7 | aauvinen | |
| 8 | H312 | 0.501 | 0.19714 | 60593 | 101502 | 6.4 | aauvinen | |
| 9 | J192 | 0.5 | 0.19635 | 61804 | 108527 | 9.4 | aauvinen | |
| 10 | K153 | 0.5 | 0.19635 | 62663 | 108611 | 7.9 | aauvinen | |
| 11 | K083 | 0.5 | 0.19635 | 64620 | 112557 | 7 | aauvinen | |
| 12 | J202 | 0.5 | 0.19635 | 63021 | 109128 | 8.4 | aauvinen |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 10/14/2024 ✔