Summary for Test 2024-08-21-60-1

Test performed: ASTM A370-20

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date08/21/2024 Sample Unique Key60
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/22/2024
Sample typeQuality Assurance A brief description of the sampleDuctile Iron Casting
The quantity of what the sample constitutes12 From where was the sample collectedManufacturer
First name of sampler or witnessed byDaniel Last name of sampler or witnessed byBishikwabo
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSDI Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM6 - Ductile Iron Cast Samples Heat Number (s)B023 B074 C064 C064 H312 I012 I222 J192 J202
Part Number (s)ACS 31 6 AH SDI 19 6 AH SDI 12 6 PC BP SDI 19 Material SpecificationA536
Grades80-55-06 Metal Foundry Manufacturer (Mill)Farrar Corporation
Prestressing ManufacturerSDI

Test Details

DIME Sample ID: 2024-08-21-60
DIME Test ID: 2024-08-21-60-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-20: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2024-10-14

Test Results


Number of Samples: 12
Input Type: Calculated
Tester's full name: aauvinen
Date of test: 09/24/2024
UTM: 67kip
Temperature: 72 F
NumSampleHeat NumberDiameter (in)Area (sqin)Stress at Offset (psi)Tensile Strength (psi)Elongation in 4 x d (%)Tested By
1J2720.50.19635649131148898.5aauvinen
2B0230.50.196356267110952910.6rmacias
3I0120.50.19635616281069889.4aauvinen
4C0640.50.19635635771112849.7aauvinen
5I2220.4990.19556620651094059.8aauvinen
6B0740.50.19635618581079548.9aauvinen
7C0640.50.19635645881121097.7aauvinen
8H3120.5010.19714605931015026.4aauvinen
9J1920.50.19635618041085279.4aauvinen
10K1530.50.19635626631086117.9aauvinen
11K0830.50.19635646201125577aauvinen
12J2020.50.19635630211091288.4aauvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph

Test was verified on 10/14/2024