Summary for Test 2024-08-14-41-31
Test performed: ASTM E23-18Project Information
| Project Identifiers | Project ID: 994675 DEA: 07390204 EFIS: 0722000334 |
|---|---|
| DIST-CO-RTE-PM | 07--- |
| Award Date | 01/24/2025 |
| Closeout Date | Not set |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 08/07/2023) |
Sample Information
| Sample Taken Date | 08/14/2024 | Sample Unique Key | 41 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/16/2024 |
| Sample type | Quality Assurance | A brief description of the sample | Steel Check Plate |
| The quantity of what the sample constitutes | 24 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | NA | Last name of sampler or witnessed by | NA |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Job Site | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | NA |
|---|---|---|---|
| Material Specification | N/A | Grade | NA |
| Thickness | NA | Shape | circle |
| Metal Foundry Manufacturer (Mill) | NA | Plate Dimension | NA |
Test Details
DIME Sample ID: 2024-08-14-41
DIME Test ID: 2024-08-14-41-31
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-18: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2024-10-01
Test Results
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 09/23/2024
Temperature Required: 70 oF
Minimum Energy Required: 0 ftlb
Test Temperature 1: 72 oF
Impact Energy 1: 25.7 ftlb
Impact Energy 2: 34.3 ftlb
Impact Energy 3: 32.6 ftlb
Striker Radius: 8
Average Impact Energy: 31 ftlb
Value Exceeds The Machine Capacity?: No
General comments (publicly viewable) (Max 1000 characters): Sample 7
Test was verified on 10/1/2024 ✔