Summary for Test 2024-09-05-91-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 993360
DEA: 023J2204
EFIS: 0222000021
DIST-CO-RTE-PM02-TEH,TEH/TEH,PLU/PLU,LAS/LAS,SHA/SHA,PLU,LAS,TEH,SHA-32,36,44,189,147,172-0/24.87, 43.95/104, 0/18.42, 0/6, 14.3/19.2, 19.01/71.39, 0/37.25, 8.9/42.3, 0/9.89, 0/1.8, 0/8.92, 0/4.4, 43.95/19.2, 62.69/37.25, 19.01/62.69, 0/21.72, 6/14.3, 0/247.87, 83/19.2
Award Date08/07/2021
Closeout Date07/27/2023
Work DescriptionRemove hazard trees, erosion control, paving, and drainage repairs in order to restore the facility.
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date09/05/2024 Sample Unique Key91
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/13/2024
Sample typeQuality Assurance A brief description of the sample1 gallon can
The quantity of what the sample constitutes1 From where was the sample collectedOther
First name of sampler or witnessed byJoel Last name of sampler or witnessed byGosik
Title of samplerRE Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameKBP Transportation Laboratory (TL) Number636955
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)24-30-891
Batch number2430891 Mix number3860

Test Details

DIME Sample ID: 2024-09-05-91
DIME Test ID: 2024-09-05-91-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2024-09-23

Test Results


Input Type: Measured
Tester's full name: Mitra Rafiei
Date of test: 09/11/2024
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 19.8
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.09
Volatile content (ASTM D 2369) 30% max: 19.8
Flash point (ASTM D 3828) more than 180 deg F: 210
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: no data
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/23/2024