Summary for Test 2024-09-19-22-2
Test performed: CTM 217-June 2011Project Information
| Project Identifiers | Project ID: 993387 DEA: 07323404 EFIS: 0716000064 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-5-R59.5/R67.9 |
| Award Date | Not set |
| Closeout Date | Not set |
| Work Description | PLACE CULVERT, REPLACE DRAINAGE SYSTEM, RECONST ROADWAY & EMBANKMENT. |
| Location Description | LOS ANGELES COUNTY AT VARIOUS LOCATIONS FROM LAKE HUGHES ROAD UNDERCROSSING TO 1.9 MILES NORTH OF TEMPLIN HIGHWAY UNDERCROSSING |
| QA Service Level | 1 (Verified on 12/06/2021) |
Sample Information
| Sample Taken Date | 09/19/2024 | Sample Unique Key | 22 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/19/2024 |
| Sample type | Acceptance | A brief description of the sample | Class II Recycled Aggregate Base |
| The quantity of what the sample constitutes | 250 cy | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Hopkins |
| Title of sampler | Plant Inspector | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Security Paving Jobsite Castaic | Transportation Laboratory (TL) Number | C091924A |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | KH114N | Structure unique identifier | |
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | Security Paving Jobsite Castaic |
|---|---|---|---|
| The fabricator's/manufacturer's product name for the sample | LCBRS | The fabricator/manufacturer designation for the sample | |
| The plant number | Security Volumetric Mixer | A detailed description of where the material sample was collected | Stockpile @ Yard |
| Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
| The concrete mix design number | G3-19-CTSLCB-165 | Lot number | |
| Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2024-09-19-22
DIME Test ID: 2024-09-19-22-2
Testing Lab: CT D07 - Plant Services
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2024-11-17
Test Results
Number of tests: 2
Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 09/20/2024
Temperature correction: 0
Temperature of solution: 75
Clay reading (test 1): 5.9
Sand reading (test 1): 3.2
Clay reading (test 2): 5.9
Sand reading (test 2): 3.2
Sand equivalent (test 1): 55
Sand equivalent (test 2): 55
Sand equivalent before temperature correction: 55
Sand equivalent after temperature correction: 55
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/17/2024 ✔