Summary for Test 2024-09-10-9-8

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 995495
DEA: 101C2704
EFIS: 1014000097
DIST-CO-RTE-PM10-STA-5-27.1
Award Date03/28/2024
Closeout DateNot set
Work DescriptionREPLACE SAFETY ROADSIDE REST AREA.
Location DescriptionSTATE HIGHWAY IN STANISLAUS COUNTY ABOUT 1.0 MILE SOUTH OF SAN JOAQUIN COUNTY LINE AT THE WESTLEY SAFETY ROADSIDE REST AREA
QA Service Level1 (Verified on 11/20/2023)

Sample Information

Sample Taken Date09/10/2024 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/18/2024
Sample typeQuality Assurance A brief description of the sample#4 2'-0" Welded Hoops
The quantity of what the sample constitutes1296 From where was the sample collectedFabricator
First name of sampler or witnessed byAdrian Last name of sampler or witnessed bySanchez
Title of sampler Telephone number of sampler2137133499
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL159-153-24 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)4141569
Hoop Manufacturer Lot Number(s)#1,5,9 Material Standard CodeASTM A706
Material Grade60 Rebar Size#4
Diameter of Hoop2'-0" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerCMC
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2024-09-10-9
DIME Test ID: 2024-09-10-9-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2024-09-19

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 09/19/2024
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
1294/13mm0.219704.1398521Ok Neckingaauvinen

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 9/19/2024