Summary for Test 2024-09-04-54-2
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
| Award Date | 02/07/2023 |
| Closeout Date | 08/29/2025 |
| Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
| Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
| QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
| Sample Taken Date | 09/04/2024 | Sample Unique Key | 54 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/12/2024 |
| Sample type | Quality Assurance | A brief description of the sample | HRC Coupler 500/510 |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Amber | Last name of sampler or witnessed by | Christian |
| Title of sampler | ASR | Telephone number of sampler | (928) 216-0101 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Camblin Steel Service | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Steel Arizona |
| Coupler Manufacturer | HRC Gerdau | Intermediate Assembler or Fabricator | |
| Rebar Size | #9 | Coupler Model | HRC 500/510 |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Rebar Hoop Fabricator | ||
| Coupler Component Heat/Lot Number(s) | 500/73131267 510/74133720 Lot 1 | Rebar Heat Number(s) | 052924 |
| Rebar Size 2 | Coupler Unique ID | TF-17-01 |
Test Details
DIME Sample ID: 2024-09-04-54
DIME Test ID: 2024-09-04-54-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2024-09-19
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 09/18/2024
UTM: 400kip
Temperature: 72.00 f
Halo ID:
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Slip (inch) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 2 | No. 9/29mm | 1 | 0 | 1 | 91915 | 91915 | Service Splice | aauvinen |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 9/19/2024 ✔