Summary for Test 2024-09-09-64-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 993119 DEA: 021J7104 EFIS: 0220000120 |
|---|---|
| DIST-CO-RTE-PM | 02-TRI-3-29.77/L30.88 |
| Award Date | 06/06/2024 |
| Closeout Date | 11/27/2024 |
| Work Description | TRINITY 3 PAVEMENT AND DRAINAGE |
| Location Description | TRINITY COUNTY NEAR DOUGLAS CITY FROM READING CREEK BRIDGE TO ROUTE 299 |
| QA Service Level | 1 (Verified on 08/23/2021) |
Sample Information
| Sample Taken Date | 09/09/2024 | Sample Unique Key | 64 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/09/2024 |
| Sample type | Production Start-Up | A brief description of the sample | RAP Sample |
| The quantity of what the sample constitutes | PSE 2 bags | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | White |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | D79711B | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Tullis — Northstate Asphalt (Redding, CA) — Latona Aggregates (Anderson, CA) | Transportation Laboratory (TL) Number | 848627 |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Tullis, Northstate Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | Aggregate Source | ||
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2024-09-09-64
DIME Test ID: 2024-09-09-64-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2024-09-19
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 09/11/2024
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7332.3 grams
Mass of oven-dry sample in air for Sample 1: 1571.5 grams
Mass of container filled with the sample and water for Sample 1: 8306.9 grams
Temperature of Water: 24 °F
Specific Gravity for Sample 1: 2.633
Theoretical maximum density at 25°C (77°F): 2625.4 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.633
Test was verified on 9/19/2024 ✔
