Summary for Test 2024-08-13-139-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994226
DEA: 042K7004
EFIS: 0417000010
COOP: 042895
DIST-CO-RTE-PM04-ALA-880-R0.0/11.8
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE)
Location DescriptionALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date08/13/2024 Sample Unique Key139
Date that the sample was received by the laboratory/organization performing the testing08/24/2024 Sample typeQuality Assurance
A brief description of the sample1/2 RHMA-O The quantity of what the sample constitutes1501-2250 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byH
Last name of sampler or witnessed bySadie Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Pleasanton
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number1
Sublot number13 HMA Mix NumberDO4 OGFC 24 001
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2024-08-13-139
DIME Test ID: 2024-08-13-139-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-18

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Henry Concepcion
Date of test: 08/24/2024
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1553.2 g
Mass Loss: 125.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.71 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/18/2024 ✔