Summary for Test 2024-09-03-56-1
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 1000061 DEA: 051Q4804 EFIS: 0523000036 |
|---|---|
| DIST-CO-RTE-PM | 05-SCR-1-R5.0/8.9 |
| Award Date | 04/10/2024 |
| Closeout Date | 04/02/2025 |
| Work Description | RHMA OVERLAY, STRIPING AND MODIFY TRAFFIC STATIONS. |
| Location Description | SANTA CRUZ COUNTY FROM 0.9 MILE NORTH OF BUENA VISTA DRIVE UNDERCROSSING TO 0.2 MILE SOUTH OF RIO DEL MAR OVERCROSSING |
| QA Service Level | 1 (Verified on 02/05/2024) |
Sample Information
| Sample Taken Date | 09/03/2024 | Sample Unique Key | 56 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/17/2024 |
| Sample type | Dispute Resolution | A brief description of the sample | 1/2" RHMA-G |
| The quantity of what the sample constitutes | 12 boxes,12 bags agg, 5 quart cans, 1 can of dust. | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Wesley | Last name of sampler or witnessed by | Rider |
| Title of sampler | TET | Telephone number of sampler | 813-818-0254 |
| Laboratory sample identification | 024-063 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Graniterock Aromas Batch plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 1/2 inch | Lot number | |
| Sublot number | HMA Mix Number | ||
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2024-09-03-56
DIME Test ID: 2024-09-03-56-1
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2024-09-18
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: James Brewster
Date of test: 09/18/2024
Test procedure used?: Method A
Mass of the specimen basket assembly: 4225.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 5872.7 g
Mass of HMA Sample prior to ignition: 1647.6 g
Mass Loss: 130.7 g
Mass of aggregate remaining after ignition: 1516.9 g
Correction Factor (Percent by mass of HMA Specimen): 0.64 %
Moisture Content: 0.01 %
Temperature Compensation Factor: 0.21 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.07 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/18/2024 ✔