Summary for Test 2024-08-02-85-3

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 994744
DEA: 072XG504
EFIS: 0723000149
DIST-CO-RTE-PM07-LA-5-66.3/67.3
Award Date03/27/2023
Closeout Date09/26/2025
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 05/04/2023)

Sample Information

Sample Taken Date08/02/2024 Sample Unique Key85
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/12/2024
Sample typeAcceptance A brief description of the sampleLCB Aggregate
The quantity of what the sample constitutes130 CY From where was the sample collectedManufacturer
First name of sampler or witnessed byvictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Santa Clarita Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0046
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the samplemix s30c393loa
The plant numberNational RM Santa Clarita A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberS30C396L0A Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2024-08-02-85
DIME Test ID: 2024-08-02-85-3
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2024-11-15

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Victor Pham
Date of test: 08/12/2024
Sieve SizeCumulative Percent Passing
100 %
94 %
86 %
66 %
42 %
19 %
6 %
3 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/15/2024